Resistance thermometer – measuring insert (data sheet 8561)
model |
TPtMiAo / TPtMiAoT |
measuring element |
Pt100 acc. to DIN EN 60 751 |
operating temperature range |
−200 / +600 °C (−328 / +1112 °F) |
ambient temperature range |
TPtMiAo: −40 / +100 °C (−40 / +212 °F) TPtMiAoT: −40 / +85 °C (−40 / +185 °F) |
accuracy |
class AA, A or B according to DIN EN 60 751 |
degree of protection |
IP00 measuring inserts are intended for the installation into protective fittings for electrical thermometers, which are equipped with an appropriate degree of protection for safe operation |
output signal |
model TPtMiAo: resistance according to DIN EN 60 751 model TPtMiAoT: 4...20 mA, HART® or PROFIBUS® PA / FOUNDATION™ Fieldbus |
Certificates
Data sheet download